Discharge Radar RQ-30 ADMS

 

WELL PROVEN RQ-30 DISCHARGE MEASUREMENT WITH DATA LOGGER AND DATA TRANSMISSION IN COMPACT Housing

The RQ-30 ADMS is an all-in-one discharge measurement System. It contains the non-contact flow velocity and water level sensors of the RQ- 30 and applies the same algorithms and model to calculate the discharge in the RQ-30 sensor.

 

The rechargeable batteries allow autonomous operation for several month and the integrated charge controller provides for an easy connection of a solar panel.  The integrated data logger of the RQ-30 ADMS offers wireless 2-way data communication. The 2-way communication makes it possible to remotely access the sensor and data logger anytime from anywhere.

 

Notifications by E-mail and SMS are a standard feature of the RQ-30 ADMS. Optionally, the RQ-30 ADMS can be equipped with a SOMMER Time laps camera for visual surveillance of the monitoring site.

 

Technical details

  • Protection class IP 66
  • Battery 24 Ah / 12 V
  • Recommended solar panel (for mid-latitude) 20 W
  • Power consumption active operation 150 mA, standby 3 mA (total system)
  • Operating temperature - 20° ... 60° C
  • Total weight 19.5 kg
  • Mischellaneous over voltage protection, reverse power protection, lightning protection

Waterlevel measurement

  • Measuring range 0 ... 15 m standard version / 0 ... 35 m extended version
  • Resolution 1 mm
  • Accuracy +/- 2 mm
  • Radar frequency 26 GHz (K-Band)
  • Radar opening angle 10°

Velocity measurement

  • Measuring range 0.08 ... 16 m/s (depening on flow conditions)
  • Accuracy +/- 0.01 m/s; +/- 1 % FS
  • Resolution 1 mm/s
  • Direction recognition +/-
  • Measurement duration 5 ... 240 sec.
  • Measurment interval 8 sec. ... 5h
  • Measuring frequency 24 GHz (K-Band)
  • Radar opening angle 12°
  • Distance to water surface 0.50 ... 35 m

Data transmission

  • Supported networks quad band EGSM 850 / 900 / 1800 / 1900 MHz networks
  • Transmission power class 4 (2W) with 850 / 900 MHz; class 1 (1W) with 1800 / 1900 MHz
  • 2G/3G/4G  up to 14.4 kbps (transparent) and 9.6 kbps (non-transparent)
  • Data transfer FTP server or HTTP server
  • MDS server: package including database, station- /user management and data visualisation via web browser

Data logger

  • Storage up to 500,000 values
  • Data readout  remotely

Additional Info

  • Characteristics: stationary measuring system
  • Features: non-contact measurement