sommer logo Partner Portal

|

+43 5523 55989

| My PDF

Filtering

Inquiry


captcha

Snow drift sensor SND

Snow drift sensor

 

Extremely robust sensor to determine snow drift intensity

The sensing part of the instrument is a cylindrical, anti-abrasion, anti-adhesion and anti-rime coated tube supported by two strong stainless steel arms. The impact of drifting snow and the friction of laminar wind induce a change in internal acoustic pressure. The excitation by snow and wind is discriminated by a specific acoustic, mechanical and electronic design.


It features continuous or pulse analog voltage outputs and supports SDI-12 communication, serial RS-232, and Modbus RTU RS485 (using an optional adapter). The amout of snow drift is returned in g/m²/s, a simple unit to interpret how much snow has been transported onto a road or an exposed slope.

 

Features and advantages

  • Maintenance-free & special design to resist the highest winds, extreme temperatures, rime, sunlight, abrasion, ashes and even temporary submersion.
  • Lightweight, corrosion free, UV/Ozone stable, non-obstructable. Resistant to shock, vibration, lightning, corrosion, humidity, animals, insects and splashes. Operating temperature from −40 °C to 80 °C (−50 °C to 100 °C extended).
  • Very low power consumption: 2.1 mA continuous for nominal operation (10% duty-cycle) or 21 mA for continuous operation.
  • Adaptable to any structure thanks to a range of high standard stainless steel clamping accessories.
  • Directly connect the sensor to your central unit or configure any analog or digital communication through the included USB dongle.
  • Compatible with almost any external analog or digital central unit, with a very long extension cable (typ. up to 200 m), with IoT (LPWAN) transceivers and industrial control systems (BMS, SCADA, etc.).

 

Fields of application

  • Monitoring of snowdrift
  • particles mass flux and wind-speed measurements
  • Meteorological and scientific applications
  • Road security and avalanche danger
  • Industrial surveillance applications

 

Technical details

  • Range particle flux 0 to 250 g/m²/s (0 to 2.5 V, or 0 to 5 V)
  • Range wind speed 0 to 250 km/h (0 to 2.5 V, or 0 to 5 V)
  • Measurement principle Acoustic pressure
  • Temperature range -40°C to +80°C (-40°F to +176°F)
  • Analog interface  0 to 2.5 V, or 0 to 5 V
  • Digital SDI-12, RS-232 TTL
  • Power supply 6 to 30 VDC
  • Power consumption <1 mA in stand-by and 20 mA in acquisition mode
  • Proteciton IP67

Additional Info

  • Characteristics: stationary measuring system
  • Features: non-contact measurement

Download attachments: