Specifications
|
Physical and environmental |
|
|---|---|
|
Power supply |
9...28 VDC; Reverse voltage protection, overvoltage protection |
|
Power consumption at 12 VDC |
1.5 Ah per day Peak current drain 91 mA Inrush current <200 mA (for a measurement interval of 60 s) |
|
Outputs |
Analog output 4…20 mA (14 bit, max. load 250 Ω) Digital output (low: 0V, high: Vsupply, max. 1.5 A) |
|
Operating temperature |
-40…60 °C (-40…140 °F) |
|
Storage temperature |
-40…60 °C (-40…140 °F) |
|
Relative humidity |
0...100 % |
|
Protection rating |
IP 68 |
|
Lightning protection |
Integrated protection against indirect lightning with a discharge capacity of 0,6 kW Ppp |
|
Housing material |
Zytel 103HSL NC010, resistant to aggressive substances typically found in sewage channels |
|
Mounting bracket |
Mounting cube Ø30 mm |
|
Size L x W x H |
272 x 152.2 x 185.5 mm (10.71 x 5.99 x 7.30 in), including mounting cube |
|
Weight |
1.55 kg (3.42 lb) |
|
Velocity |
|
|
Detectable measurement range |
0.08…16 m/s (depending on waves) |
|
Accuracy |
± 0.01 m/s (certified by METAS) |
|
Resolution |
1 mm/s |
|
Direction recognition |
+/- |
|
Measurement duration |
5…240 s |
|
Measurement interval |
8 s…5 h |
|
Measurement frequency |
24 GHz (K-Band) |
|
Radar opening angle |
12° |
|
Distance to water surface |
0.05…35 m (0.16...114.83 ft) |
|
Vertical inclination |
Measured internally |
|
Automatic vertical angle compensation |
|
|
Accuracy |
± 1 ° |
|
Resolution |
± 0.1 ° |
|
Water level |
|
|---|---|
|
Measurement range (distance between level sensor and water surface) |
0.05…8 m (0.16…26.25 ft) |
|
Accuracy |
≤ 2 mm |
|
W-band (80 GHz technology) |
W-band (80 GHz) |
|
Opening angle |
8° |