Measurement trigger

generic-measurement-trigger

Measurements are initiated by one of the options listed in the table below.

The commands to trigger measurements via RS-485 and SDI-12 are described in Communication.

Measured data are either returned directly after the measurement or can be requested by commands via the RS-485 or SDI-12 interface. The format of the returned data can be configured in the sub-menu Protocol type.

ID

Option

Description

1

Interval (default)

Measurements are initiated in a specified interval.

2

TRIG input

Measurements are triggered by the positive edge of a DC-voltage signal applied to the TRIG input (low: 0 ... 0.6 V, high: 2.2 ... 28 V, pulse duration must be ≥500 ms, delay between pulses must be ≥500 ms)

3

SDI-12/RS-485

Measurements are externally triggered by commands via RS-485 or SDI‑12 from ,e.g. a data logger.

4

all allowed

Measurement is triggered by all options mentioned above.